Energy/BTU Magnetic Flow Meter
ALMAG-EG
Features
Specifications
Installation
PDF files
Additional Images
Resources
Features
- Available with a wide range of liner materials
- Fluid Velocity range of 0-32 feet/sec, with good results for low flow applications
- Flange-type process connections are standard; ANSI, DIN, JIS style available
- Ideal for energy management applications
- Non-invasive measuring technique provides low pressure loss and excellent particle tolerance
- FEP liner available for vacuum pressure applications
- High accuracy – ±0.5% of reading standard or ±0.2% of range
- Bi-directional measurement
- Available with PT100 and PT1000 temperature sensors
Specifications
Sizes: | ½” ~ 120″ (15 ~ 3000mm) |
Measuring Range: | 0.9 – 32 feet/sec (0.9 – 10 m/s) |
Temperature: | w/ integral electronics: 15~140 °F (-10~60 °C) |
Accuracy: | ±0.5% of reading ±0.2% of FS |
Process Connection: | Flange, wafer |
Liner: | Polyurethane, Neoprene, FEP (up to 12″), PTFE |
Flange Types: | JIS, ANSI, PN |
Material : | SS #304 flow tube, carbon steel flanges & coil housing, powder coated aluminum electrical enclosure |
Conductivity: | must be ≥ 5 µS/cm |
Electrode & Grounding: | Stainless Steel #316L / Hastelloy B / Hastelloy C / Titanium / Tantalum / Platinum -iridium alloy |
Display: | Flow rate, flow velocity, percentage, Total flow, total energy flow |
Grounding Resistance: | Must be less then 10 Ω |
Protection: | IP 65 or IP 68 (Submersible, with remote style) |
Ambient Tempearture: | -15~140 °F (-25~60 °C) |
Cable entry: | 2 X PG11 |
Power Consumption: | ≤ 15 Watts |
Installation
Tab Content
PDF files
Product Files
Additional Images
Resources
The ALMAGEG is an in-line electromagnetic energy flowmeter ideal for conductive liquids. A wide variety of sizes are available to accommodate nominal pipe diameters ranging from ½” through 120″. The ALMAGEG may be used in many applications that require accurate thermal energy measurement such as chilled water, hot water and condenser water systems. The ALMAGEG magmeter is available in a stand- alone configuration and may also be used with various SMC transmitter and display packages.