[ALHPD]
Two highly accurate cycloid-shaped screw spindles mesh and rotate inside a cylindrical housing with two overlapping holes in the form of a figure 8, which forms the measuring chamber. Liquid flows in axial direction and rotates the spindles; it is forced along the measuring chamber bores by the profile of the spindles. This occurs without pulsation and with minimum leakage. An inductive pickoff will detect the speed of the spindle pair through the housing via a pole wheel with a high number of gears. The speed of the spindles is directly proportional to the volumetric flow rate over a very wide range. This sensor will output a highly accurate pulse train or an analog 4-20 mA signal when used in conjunction with the ALVTM local display unit. All units come factory calibrated under conditions that match the end user’s operating viscosity as closely as possible in order to determine the optimal K-factor (pulses per unit volume).
This is Modal Title
Click image to enlarge
- High accuracy and wide turndown ratios; up to 400:1
- Suitable for pressures up to 5800 psig (400 bar)
- Low pressure drop compared with other positive displacement meters
- Double pulse rate and reverse-flow detection possible
- Pulsation-free measurement, readings unaffeted by pulsating flows
- High quality materials and bearings provide superior corrosion resistance
- Low operating noise
- Ex-protection EExiaIICT6 for zone 1
Process Connections: | ¼”-1½” FNPT |
Process temperature: | up to 300°F (150°C); higher upon request |
Operating pressure: | 5800 psig (400 bar) max. |
Flow rates: | 0.002 to 105 GPM (0.01 to 400 LPM) |
Repeatability: | ±0.10% |
Viscosities: | 30 up to 1,000,000 cSt (below 30 cSt with restricted measuring range and vertical mounting) |
Linearity: | ±0.50% of actual flow value (from 30 mm²/s up)±0.25% of actual flow value (from 100 mm²/s up) |
Material : | SS DIN 1.4571/1.4435 (SS316 Ti/316L) |
Supply Voltage VB (blind pulse amplifier): | +8.5 up to 29 VDC, regulated; < 5 mA current draw |
Frequency Range (blind pulse amplifier): | 2 up to 4,000 Hz |
Max. process temperature (blind pulse amplifier): | 250 °F with a distance of at least 1″ between flowmeter and electronic housing; 300 °F w/ at least 2½” |
Integral LCD display option: | 8 digits (14 segments), digit height ¼” (7mm) for real-time value, totals and programmable |
Supply Voltage (LCD display option): | 14-30 VDC controlled,VB = (Rload x 20 mA) + 14 V |
Analog output (LCD display option): | 2-wire (4-20mA); 12 bit (3.9 µA) resolution |
Weight: | Flowmeters : 0.5 to 77 lbs (2.5 to 35 kg)Electronics : 0.5 to 5.5 lbs (0.25 kg to 2.5 kg) |
Frequency output (LCD display option): | fmax: 3,000 Hz, duty cycle: approx. 1:1, |
Ex-protection: | II 2 G Eex ia IIC T4, BVS 03 ATEX E 205 |
Process temperature (LCD display option): | -40~ 248 °F (-40~120 °C) w/ a distance of ≥ ½” (15 mm) between flowmeter and electronics |
Ambient temperature (LCD display option): | -40 up to 158 °F (-40 up to 70 °C) |
Housing: | IP 65, aluminum AlMgSiPb, blue anodized |