Multi-Channel Transit-Time Gas
ALSONIC-DSP-100GC
- Non-invasive clamp-on ultrasonic sensors; no pipe cutting
- Wide velocity range from 0.05 to 30 m/s
- Wide measuring range of 200:1
- No moving parts and no pressure loss
- Field diagnostics with signal shape, gain, Delta T, and FFT
- Temperature sensing and volume compensation
- Simple installation and maintenance
- Standard (two-path) and explosion-proof (single-path) transmitter options
| Measuring Principle: | Transit time ultrasonic |
| Operating pressure: | >5 barg (75 PSIG) |
| Velocity: | 0.05-30 m/s, bidirectional |
| Measuring Range: | 200:1 |
| Accuracy: | ±1.0% of reading |
| Reproducibility: | 0.25% |
| Diagnostics: | Signal shape, gain, Delta T, FFT |
| Pipe Material: | Natural gas, fuel gas, compressed air |
| Transmitter: | Standard: two-path; Ex: single-path |
| Protection: | Standard IP65; Ex: Ex ia IIC T6 Ga / Ex db IIC T6 Gb |
| Temperature: | -20 to +80 C (transmitter) |
| Power: | AC 110-220 V; DC 12-24 V (option) |
| VO: | 2 digital outputs; 2 x 4-20 mA outputs; 1 x 4-20 mA input |
| Interface: | RS-232C; RS-485 (Modbus) |
| Transducers: | 316 SS, IP68; DN50-300 mm |
Transducer Specification
Standard transducers, Fluid Temperature : -5 ~ 250 °F (-20 ~ +120 ℃ )
| Model | A | B | C | D | Pipe Size (Nominal) |
| XLC | 1.38″ (35 mm) | 2.56″ (65 mm) | 1.45″ (37 mm) | 4.35″ (110.5 mm) | 2″ ~ 10″ (DN 50 ~ 250 mm) |
| XLD | 1.38″ (35 mm) | 3.66″ (93 mm) | 1.97″ (50 mm) | 3.38″ (86 mm) | 8″ ~ 20″ (DN200~500mm) |
Transmitter Comparison
| Parameter | 100LGC | 10LXGC |
| Measurement paths | Two-path | Single-path |
| Enclosure | IP65 | Ex ia IIC T6 Ga / Ex db IIC T6 Gb |
| Power | AC 110-220 V | DC 12-24 V (AC option) |
| Temperature | -20 to +80 °C | -20 to +80 °C |
| Communications | RS-232C / RS-485 | RS-232C / RS-485 |
Mounting Track Size
| Model | a | b | c | d |
| M-XLC | 1.57″ (40 mm) | 14.96″ (380 mm) | 1.38″ (35 mm) | 1.69″ (43 mm) |
| M-XLD | 1.57″ (40 mm) | 27.55″ (700 mm) | 1.38″ (35 mm) | 1.69″ (43 mm) |


Application Information
Please contact your SmartMeasurement application engineer. You also need to provide the following information:
| GAS / FLUID | Gas composition, operating density and viscosity |
| PIPE SIZE | Nominal diameter, outside diameter and wall thickness |
| PRESSURE/TEMPERATURE | Normal and maximum operating pressure and temperature |
| PIPE MATERIAL | Material, lining and thickness, if applicable |
| INSTALLATION | Straight pipe lengths, site classification and mounting conditions |
| ELECTRONICS | Required outputs, power and communication interface |
SMARTMEASUREMENT’s ALSONIC DSP-100GC series is a fixed-mount, transit-time ultrasonic flowmeter with clamp-on transducers for non-invasive gas measurement at pressures greater than 5 barg (75 PSIG).
Its fine-time measurement technology uses ultrasonic beams sampled at picosecond intervals. Digital signal processing, cross-correlation, and fast Fourier transform (FFT) techniques improve signal-to-noise performance for accurate, drift-free flow measurement.
The standard transmitter provides two-path measurement with 316SS clamp-on transducers, and the explosion-proof transmitter provides single-path measurement for hazardous-area gas flow measurement. Both include a graphic LCD display, field diagnostics with signal shape, gain, Delta T, and FFT, and RS-232C/RS-485 (Modbus) communications.