Ultra Low Flow Small Line Size Ultrasonic Flow Meters
ALSONIC-MN2 (ALSONIC-MINI-2)
- Available in Standard: ⅜”~1 ½” (DN10~DN40) & Optional: ¼” (DN8) pipe sizes
- Will measure a wide range of fluid velocities; 0.08m/s~10m/s
- Data logger includes daily, monthly and total
- Outputs include 4-20mA, alarms and MODBUS RTU
- Suitable pipe materials including: Metal, PVC, PP, PE or PVDF rigid plastic pipe
- Accuracy; Std: 3%FS, Opt: 1.5%FS
- Energy and BTU measurement optional
- NIST traceable calibration certificate
Measuring Principle: | Transit time ultrasonic |
Pipe Size: | Std: ⅜”~1½” (DN10~DN40); Opt: ¼” (DN8) |
Accuracy: | Std: 3%FS; Opt: 1.5%FS |
Enclosure material: | Polypropylene |
Enclosure Protection Class: | IP54 |
Velocity: | 0.08m/s~10m/s |
Analog output: | 4~20mA |
Communication: | RS485/Modbus |
Response Time: | 0.5s~3s |
Power supply: | 20~28VDC, 300 mA |
Power Consumption: | 1W |
Media: | Water, clean liquids w/<2% TSS. Contact Factory for unusual fluid media. |
Display: | 1.5″ OLED display |
Mounting Screw: | SS# 304 |
Keyboard: | 2 button |
Pipe materials: | Metal, PVC, PP, PE or PVDF rigid plastic pipe (Contact factory for others) |
Ambient temperature: | (14°F~140°F) -10°C~60°C |
Media temp: | Std. (14°F~149°F) 0°C~65°C (non-frozen); Opt. (14°F~221°F) 0°C~105°C (non-frozen) |
Power and I/O connection: | M12-A type plug, (Five-pin) |
Vibration resistance: | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each XYZ axis |
Impact resistantance: | 100 m/s2 16 ms pulse, 1000 times each for X, Y and Z axis |
Product Files
ALSONIC-MINI-2 Catalog
Extra Images
SmartMeasurement’s ALSONIC MN2 is a special-purpose clamp-on ultrasonic meter designed for small line sizes and ultra-low flow rate applications where traditional clamp-on meters would not ordinarily be feasible. This device features a compact, easy-to-install design with transducers that are integrated with the display module. Installation may be performed without cutting the pipe or shutting down the process and there is no need to manually adjust the transducer spacing.
This meter can be used with virtually any clean liquid containing less than 2% total suspended solids and does not require the media to be electrically conductive. It can be used with both metallic and non-metallic pipes and tubes. Industries and applications where this device has been successfully deployed, include Food & Beverage, Automotive, Chemical processing, and dosing/mixing applications.